TH-6F usoro ọrụ mmegharị
Thelọ Ọrụ Ntanetị The Ethernet Tee Ethernet bụ ụlọ ọrụ na-arụ ọrụ na-enweghị ike nke na-enweghị ntụkwasị obi ngwọta ike maka SMBS na-enye ike na netwọkụ Ethernet. Ekele ya na ihe eji eme ya na nke ike ya, ihe a na-azọ nzọpụta a bụ nhọrọ kachasị mma maka azụmahịa chọrọ ike arụmọrụ na-enweghị ọrụ ọrụ.
N'agbanyeghị nha kọmpat ya, nke a na-anapụta ntụkwasị obi pụrụ iche, na-eme ka ọ zuo oke maka ọrụ mmepụta na-aga n'ihu na gburugburu ọgba aghara na gburugburu ọgba aghara. Ma ịkwesịrị ibugharị ya n'ejiptlọ ọrụ na-agafe agafe, ala ụlọ ọrụ, na gburugburu ọnọdụ okpomọkụ nke dị ala ma ọ bụ dị elu nke sitere na -40 ℃ ruo + 75 ℃ ruo 75 ℃ ruo na ọnọdụ siri ike ma na-arụ enweghị ntụpọ.
Nke a na-agbanyụ na-enye gị mfe nke mmezi na ịdị mma na-enweghị mgbagha, yabụ ị nwere ike itinyekwu oge na-elekwasị anya na azụmaahịa gị. The TH-6F na-abịa na njiri nche nke notch na-echebe netwọ gị na data site na nnweta na-enweghị ikike.

● mesoo IEEE 802.3, Iee 802.3.EE 802.3AF, IEEE 802.3.
● Nchọpụta Auto- MDI / MDI-X
Atụmatụ na-echekwa ụzọ na-aga n'ihu na nzacha ikuku na ọnụego
● Na-akwado nha ngwugwu ruru 10k bytes
● Nchedo IP40 zuru ezu, ihe eji eme ihe, ihe eji eme ihe, dị elu / nke dị ala na-eguzogide -40 ℃ ℃
DC48v-58V ndenye
CSMA / CD Protocol
● Automatic na-akpaghị aka na agụmakwụkwọ na ịka nká
P / n n | Ọdụ ụgbọ mmiri |
TH-6F0005 (p) | 5 * 10 / 100mpps Ethernet Port (4xpoe) |
TH-6F0008 (p) | 8 * 10 / 100mbps Ethernet Port (8xpoe) |
TH-6F0104 (p) | 4 * 10 / 100mpps Ethernet Poe Port, 1 * 1000MBPS SFPOnu mmiri |
TH-6F0108 (p) | 8 * 10 / 100mpps Ethernet Poe Port, 1 * 1000MBPS SFPOnu mmiri |
TH-6F0204 (p) | 4 * 10 / 100mbps Ethernet Poe Port, 2 * 1000MBPS SFPOnu mmiri |
TH-6F0208 (p) | 8 * 10 / 100mbps Ethernet Poe Port, 2 * 1000MBPS SFPOnu mmiri |
TH-6F0408 (p) | 8 * 10 / 100mpps Ethernet Poe Port, 4 * 1000MBPS SFPOnu mmiri |
Onye na-eweta ọdụ ụgbọ mmiri na-eweta | |
Ike interface | Phoenix Publinal, ntinye aka |
Egosiputa ihe ngosi | PWR, Opt, nmc, alm |
Typedị eriri USB & Mbufe | |
Gbagọrọ agbagọ-abụọ | 0-100m (cat5e, cat6) |
Eriri anya mono-mode | 20/40/60/80 / 100km |
Eriri oghere | 550m |
Topology Topology | |
Topology | Akwadoghị |
Topology | Onyenjideaka |
Ọnụ ahịa bọs | Onyenjideaka |
Topology osisi | Onyenjideaka |
Nkwado uri | |
Poraon | 1-4/1-8 |
Standard Standard | Ieee 802.3af, Ieee 802.3at |
Utu | 1, 2, 3, 6 |
Ngbanwe eji arụ ọrụ | DC48-58vitinye ihe |
Ike zuru oke | <126w/<246w/<250w |
Oyi akwa 2 | |
Na-agbanwe ike | 10GB/14GBps/26GBPS/36GB |
PASTET na-ebugharị ọnụego | 7.44mpps/19.34mpps/10.416mps/26.78mps |
Tebụl Mac Adreesị | 8K/Iri 16k |
Gogo | 1M/2M/12m |
Na-ebugharị oge | <5us/<10us |
Mdx / midx | Onyenjideaka |
Mkpoku jumbo | Nkwado 10k Bytes |
Port na-apụ apụ | Onyenjideaka |
ItinyeSiwiich | |
1 i / r | Imegharia PD |
2Vlan | Vlan |
3 Q / I | Port na-apụ apụ |
4 f / p | VIP PARPRUPR & QOS |
Envision | |
Okpomọkụ | -40 ℃ ℃ ~ + 75 ℃ |
Ebe nchekwa | -40 ℃ ℃ ~ + 85 ℃ |
Iru mmiri | 10% ~ 95% (anaghị emegharị) |
Thermaszọ ikuku | Ihe omume na-enweghị isi, ịnwụ anwụ |
Mtbf | 100,000 awa |
Ihe eji eme ihe | |
Size | 143 * 104 * 48mm |
EGO EGO | Din-Trail |
Nha ịbụ | 0.6kgs/0.7kgs |
ENchedo Mc & Insick | |
IP ọkwa | IP40 |
Nchedo nke ike | IEC 61000-5-5 last x (6kV / 4kv) (8/20) |
Nchedo nke Othernet Port | IEC 61000-5-5 dị larịị 4 (4kV / 4KV) (10 / 700us) |
RS | IEC 61000-4-3 larịị 3 (10V / m) |
EFi | IEC 61000-4 larịị 3 (1V / 2v) |
CS | IEC 61000-6-6 larịị 3 (10V / m) |
PFMF | IEC 61000-8-8 larịị 4 (30a / m) |
Itinye | IEC 61000-4-11 larịị 3 (10v) |
ESD | IEC 61000-23 nke 4 (8K / 15K) |
Free ọdịda | 0.5m |
Ceticate | |
Asambodo nchekwa | CE, FCC, ROHS |
TH-6F0005P
TH-6F0008P
TH-6F0104P
TH-6F0108P
TH-6F0204P
TH-6F0208P
TH-6F0408P