Usoro TH-G3 Industrial Ethernet Switch
Usoro TH-G3 bụ igwe nrụpụta Ethernet dị elu nke na-enye nnyefe data Ethernet kwụsiri ike na ntụkwasị obi. Site na nhazi nke ọgbọ na-esote, na-eme ka ọ bụrụ ihe zuru oke maka njikwa netwọk nke ọma. Mgbanwe ahụ na-akwado ntinye ọkụ ọkụ abụọ ejighi arụ ọrụ (9 ~ 56VDC) iji wepụta njikọta na-akwụsịghị akwụsị, na-ahụ na ngwa azụmahịa dị mkpa na-anọgide na-adị mgbe niile. Ihe ngbanwe Ethernet nke ụlọ ọrụ na-arụ ọrụ n'ime usoro okpomọkụ nke na-arụ ọrụ nke -40 ruo 75 Celsius dị mfe, na-eme ka ọ dị mma maka ịrụ ọrụ na ọnọdụ siri ike. Usoro TH-G3 nwere ma DIN Rail na nkwado mgbidi, na-enye nchebe IP40 nke na-eme ka ọ dị mma maka iji na gburugburu ebe siri ike. Ọrụ ya nke a pụrụ ịdabere na ya, n'akụkụ atụmatụ ya dị iche iche, na-eme ka ọ bụrụ ezigbo nhọrọ maka ụlọ ọrụ na-achọ mgbanwe Ethernet ụlọ ọrụ a pụrụ ịdabere na ya.
● Kwado ihe nchekwa ngwugwu 1Mbit.
● Nkwado IEEE802.3/802.3u/802.3ab/802.3z/802.3x.
● Kwado ntinye ike ugboro abụọ 9 ~ 56VDC.
● -40 ~ 75 ° C ọrụ okpomọkụ maka ọnọdụ ọjọọ.
● IP40 Aluminom ikpe, ọ dịghị fan imewe.
● Usoro ntinye: DIN Rail / mgbidi mgbidi.
Aha Nlereanya | Nkọwa |
TH-G302-1F | Ụlọ ọrụ anaghị achịkwa mgba ọkụ na 1 × 10/100/ 1000Base-TX RJ45 ọdụ ụgbọ mmiri na 1 × 100/ 1000Base-FX (SC / ST / FC nhọrọ). abụọ ike ntinye voltaji 9 ~ 56VDC |
Njikọ Ethernet |
| |
ọdụ ụgbọ mmiri | TH-G302-1F | 1 × 10/ 100/ 1000Base-TX RJ45 ọdụ ụgbọ mmiri na 1x1000Base-FX |
TH-G302-1SFP | 1 × 10/ 100/ 1000Base-TX RJ45 ọdụ ụgbọ mmiri na 1x1000Base-FX | |
TH-G303-1F | 2×10/100/1000Base-TX RJ45 ọdụ ụgbọ mmiri na 1x1000Base-FX | |
TH-G303-1SFP | 2×10/100/1000Base-TX RJ45 ọdụ ụgbọ mmiri na 1x1000Base-FX | |
Ọnụ ntinye ike | Oghere pin-ise nwere oghere 3.81mm | |
Ụkpụrụ | IEEE 802.3 maka 10BaseT IEEE 802.3u maka 100BaseT (X) na 100BaseFX IEEE 802.3ab maka 1000BaseT (X) IEEE 802.3x maka njikwa ọsọ IEEE 802. 1D-2004 maka Usoro Protocol Osisi IEEE 802. 1w maka Protocol Osisi na-agba ọsọ ọsọ IEEE 802. 1p maka klas nke ọrụ IEEE 802. 1Q maka VLAN Tagging | |
Nha ihe nchekwa ngwugwu | 1M | |
Ogologo ngwugwu kacha | 10K | |
Tebụl adreesị MAC | 2K | |
Ụdị nnyefe | Chekwaa ma gaa n'ihu (ụdị zuru oke/ọkara duplex) | |
Gbanwee Ngwongwo | Oge igbu oge <7 μs | |
Bandiwidi azụ azụ | 1.8Gbps | |
Ike |
| |
Ntinye ike | Ntinye ike abụọ 9-56VDC | |
Oriri ike | Ibu zuru oke <3W | |
Njirimara anụ ahụ |
| |
Ebe obibi | Aluminom akpa | |
Akụkụ | 120mm x 90mm x 35mm (L x W x H) | |
Ibu | 320g | |
Ụdị nwụnye | DIN Rail na mgbidi mgbidi | |
Environment na-arụ ọrụ |
| |
Okpomọkụ na-arụ ọrụ | -40C ~ 75C (-40 ruo 167 ℉) | |
Iru mmiri na-arụ ọrụ | 5% ~ 90% (na-abụghị condensing) | |
Okpomọkụ nchekwa | -40C ~ 85C (-40 ruo 185 ℉) | |
Akwụkwọ ikike |
| |
MTBF | 500000 awa | |
Oge nrụrụ aka | Afọ ise | |
Ụkpụrụ Asambodo | FCC Part15 Klas A CE-EMC/LVD ROSH IEC 60068-2-27 (ujo) IEC 60068-2-6 (Mmajiji) IEC 60068-2-32 (ọdịda efu) | IEC 61000-4-2 (ESD): Ọkwa 4 IEC 61000-4-3 (RS): Ọkwa 4 IEC 61000-4-2 (EFT): Ọkwa 4 IEC 61000-4-2 (Ọrịa): Ọkwa 4 IEC 61000-4-2 (CS): Ọkwa 3 IEC 61000-4-2 (PFMP): Ọkwa 5 |