TH-310-2G4F Industrial Ethernet mgbanwe
TH-310-2G4F bụ mgbanwe Ethernet nke ụlọ ọrụ na-arụ ọrụ dị elu na-elekwasị anya na ntụkwasị obi, ọsọ, nchekwa, na nlekọta dị mfe. Ejiri ya na ọdụ ụgbọ mmiri 4 × 10 / 100Base-TX RJ45, 4 × 100BASE-FX ọdụ ụgbọ mmiri (SC / ST / FC), yana ọdụ ụgbọ mmiri 2 × 1000M, mgba ọkụ a nwere ike ibunye data na oke ọsọ n'elu ma ọla kọpa na eriri fiber optic. Nhazi ya siri ike na-enye ya ohere iguzogide gburugburu ụlọ ọrụ mmepụta ihe siri ike, yana okpomọkụ na-arụ ọrụ sitere na -40 ruo 75 Celsius C yana nchebe pụọ na ujo, ịma jijiji na nnyonye anya electromagnetic.
● 8 × 10/100ase-TX RJ45 ọdụ ụgbọ mmiri na 2x 1000Mbps Combo Ports
● Kwado ihe nchekwa ngwugwu 1Mbit
● Nkwado IEEE802.3/802.3u/802.3ab/802.3z/802.3x
● Kwado ntinye ike ugboro abụọ 12 ~ 36VDC
● -40 ~ 75 ° C ọrụ okpomọkụ maka ọnọdụ ọjọọ
● IP40 Aluminom ikpe, ọ dịghị fan imewe
● Usoro ntinye: DIN Rail / mgbidi mgbidi
Aha Nlereanya | Nkọwa |
TH-310-2G | Industrial unmanged mgba ọkụ na 8 × 10/100Base-TX RJ45 ọdụ ụgbọ mmiri na 2x1000MCombo Ports, dual ike input voltaji 12~36VDC |
TH-310-2G4F | Industrial unmanged mgba ọkụ na 4 × 10/100Base-TX RJ45 ọdụ ụgbọ mmiri, 4x100BASE-FXFiber ọdụ ụgbọ mmiri (SC / ST / FC) na 2x1000M Combo Ports, dual ike ntinye voltaji 12~36VDC |
Njikọ Ethernet | ||
ọdụ ụgbọ mmiri | 4×10/100Base-TX RJ45 ọdụ ụgbọ mmiri,4x100BASE-FX Fiber ọdụ ụgbọ mmiri (SC/ST/FC) na 2x1000M Combo Ports | |
Ọnụ ntinye ike | Ọnụ ntụtụ anọ nwere oghere 5.08mm | |
Ụkpụrụ | IEEE 802.3 maka 10BaseTIEE 802.3u maka 100BaseT (X) na 100BaseFX IEEE 802.3ab maka 1000BaseT (X) IEEE 802.3x maka njikwa ọsọ IEEE 802.1D-2004 maka Usoro Protocol Osisi IEEE 802.1w maka Protocol Osisi na-agba ọsọ ọsọ IEEE 802.1p maka klaasị ọrụ IEEE 802.1Q maka VLAN Tagging | |
Nha ihe nchekwa ngwugwu | 3M | |
Ogologo ngwugwu kacha | 10K | |
Tebụl adreesị MAC | 2K | |
Ụdị nnyefe | Chekwaa ma gaa n'ihu (ụdị zuru oke/ọkara duplex) | |
Gbanwee Ngwongwo | Oge igbu oge <7μs | |
Bandiwidi azụ azụ | 8.8Gbps | |
Ike | ||
Ntinye ike | Ntinye ike abụọ 12-36VDC | |
Oriri ike | Ibu zuru oke <10W | |
Njirimara anụ ahụ | ||
Ebe obibi | Aluminom akpa | |
Akụkụ | 151mm x 134mm x 47mm (L x W x H) | |
Ibu | 450g | |
Ụdị nwụnye | DIN Rail na mgbidi mgbidi | |
Environment na-arụ ọrụ | ||
Okpomọkụ na-arụ ọrụ | -40℃ ~ 75℃ (-40 ruo 167 ℉) | |
Iru mmiri na-arụ ọrụ | 5% ~ 90% (na-abụghị condensing) | |
Okpomọkụ nchekwa | -40℃ ~ 85℃ (-40 ruo 185 ℉) | |
Akwụkwọ ikike | ||
MTBF | 500000 awa | |
Oge nrụrụ aka | Afọ ise | |
Ụkpụrụ Asambodo | FCC Part15 Klas ACE-EMC/LVD ROSH IEC 60068-2-27(Ujo) | IEC 61000-4-2(ESD:Ọkwa 4IEC 61000-4-3(RS:Ọkwa 4 IEC 61000-4-2(EFT:Ọkwa 4 IEC 61000-4-2(Mwapụta:Ọkwa 4 |
IEC 60068-2-6(Mmaji) | IEC 61000-4-2(CS:Ọkwa 3 | |
IEC 60068-2-32(Ụda efu) | IEC 61000-4-2(PFMP:Ọkwa 5 |