TH-G506-2SFP Smart Industrial Ethernet mgbanwe

Nọmba nlereanya: TH-G506-2SFP

Ụdị:Todahika

  • Ntinye ike DC12-58V na AC100 ~ 240V
  • Shell IP40 ọkwa nchebe, ihe na-adịghị mma

Nkọwa ngwaahịa

Atụmatụ

Ozi ịtụ

Nkọwapụta

Akụkụ

Mkpado ngwaahịa

Nkọwa ngwaahịa

TH-G506-2SFP bụ ọgbọ ọhụrụ nrụpụta ike na-agbanwe Ethernet na 4-Port 10/100/1000Bas-TX na 2-Port 100/1000 Base-FX Fast SFP nke na-enye nnyefe Ethernet kwụsiri ike.

Ọ na-enye mgbanwe maka ụdị njikọ netwọkụ dị iche iche.A na-ejikwa mgba ọkụ a, nke pụtara na enwere ike ịhazi ya ma nyochaa ya maka ịrụ ọrụ kacha mma.Ọ na-akwadokarị atụmatụ dị elu dị ka VLAN, njikwa QoS, yana nwekwara ike ịkwado ụkpụrụ dị ka RSTP na STP maka redundancy na mgbake ngwa ngwa ma ọ bụrụ na ọdịda netwọk.

TH-8G0024M2P

  • Nke gara aga:
  • Osote:

  • ● 4 × 10/100/1000Base-TX RJ45 ọdụ ụgbọ mmiri na 2 × 100/1000Base-FX Fast SFP ọdụ ụgbọ mmiri.Mgbanwe a na-adọrọ adọrọ na-egosipụta mgbanwe DIP nke na-akwado RSTP/VLAN/SPEED, na-enye ohere maka mgbanwe na nhazi kachasị.Site na nkwado maka 9K bytes jumbo frame, mgba ọkụ a dakọtara na usoro ndọtị dị iche iche, na-eme ka ọ bụrụ ezigbo ngwọta maka mkpa netwọk dị iche iche.

    ● Ọzọkwa, mgba ọkụ anyị na-agụnye IEEE802.3az ike na-arụ ọrụ nke ọma Ethernet teknụzụ, na-eme ka ike dị mma na ibelata mmetụta gburugburu ebe obibi.Ezubere ya na ilekwasị anya na ịdịte aka na ntụkwasị obi, mgba ọkụ a na-egosipụta nchebe ọkụ eletrik 4KV, na-eme ka ọ dị mma maka iji ya na gburugburu mpụga ebe ihe ize ndụ nke ịgbanye ọkụ eletrik dị elu.

    ● Ọzọkwa, ngwaahịa anyị na-agụnye ihe ntinye ike ntinye nchedo polarity, na-enye nchekwa nchekwa ọzọ n'oge ntinye na arụ ọrụ.Igwe aluminom na ihe na-enweghị fan na-eme ka ikpochapụ ọkụ dị mma

    Aha Nlereanya Nkọwa
    TH-G506-2SFP 4 × 10/100/1000Base-TX RJ45 ọdụ ụgbọ mmiri, 2×100/1000Base-FX SFP ọdụ ụgbọ mmiri na DIP Switch, ntinye voltaji 956VDC
    TH-G506-4E2SFP 4 × 10/100/1000Base-TX POE RJ45 ọdụ ụgbọ mmiri, 2×100/1000Base-FX SFP ọdụ ụgbọ mmiri na DIP Switch, ntinye voltaji 4856VDC
    Ethernet Interface
    ọdụ ụgbọ mmiri 4×10/100/1000BASE-TX RJ45, 2x1000BASE-X SFP
    Ụkpụrụ IEEE 802.3 maka 10BaseT

    IEEE 802.3u maka 100BaseT (X) na 100BaseFX

    IEEE 802.3ab maka 1000BaseT (X)

    IEEE 802.3z maka 1000BaseSX/LX/LHX/ZX

    IEEE 802.3x maka njikwa ọsọ

    IEEE 802.1D-2004 maka Usoro Protocol Osisi

    IEEE 802.1w maka Protocol Osisi na-agba ọsọ ọsọ

    IEEE 802.1p maka klaasị ọrụ

    IEEE 802.1Q maka VLAN Tagging

    Nha ihe nchekwa ngwugwu 2M
    Ogologo ngwugwu kacha 16K
    Tebụl adreesị MAC 4K
    Ụdị nnyefe Chekwaa ma gaa n'ihu (ụdị zuru oke/ọkara duplex)
    Gbanwee Ngwongwo Oge igbu oge: <7μs
    Bandiwidi azụ azụ 20Gbps
    POE(nhọrọ)
    Ụkpụrụ POE IEEE 802.3af/IEEE 802.3 na POE
    oriri POE Ọdụ ụgbọ mmiri ọ bụla max 30W
    Ike
    Ntinye ike Ntinye ike abụọ 9-56VDC maka ndị na-abụghị POE yana 48 ~ 56VDC maka POE
    Oriri ike Ibu zuru oke <10W(na-abụghị POE);Ibu zuru oke <130W(POE)
    Njirimara anụ ahụ
    Ebe obibi Aluminom akpa
    Akụkụ 120mm x 90mm x 35mm (L x W x H)
    Ibu 350g
    Ụdị nwụnye DIN Rail na mgbidi mgbidi
    Environment na-arụ ọrụ
    Okpomọkụ na-arụ ọrụ -40℃ ~ 75℃ (-40 ruo 167 ℉)
    Iru mmiri na-arụ ọrụ 5% ~ 90% (na-abụghị condensing)
    Okpomọkụ nchekwa -40℃ ~ 85℃ (-40 ruo 185 ℉)
    Akwụkwọ ikike
    MTBF 500000 awa
    Oge nrụrụ aka Afọ ise
    Ụkpụrụ Asambodo FCC Part15 Klas A

    CE-EMC/LVD

    ROSH

    IEC 60068-2-27(Ujo)

    IEC 60068-2-6(Mmaji)

    IEC 60068-2-32(Ọdịda efu)

    IEC 61000-4-2(ESDỌkwa 4

    IEC 61000-4-3(RSỌkwa 4

    IEC 61000-4-2(EFTỌkwa 4

    IEC 61000-4-2(MwapụtaỌkwa 4

    IEC 61000-4-2(CSỌkwa 3

    IEC 61000-4-2(PFMPỌkwa 5

    Ọrụ ngwanrọ Otu igodo maka RSTP ON / Gbanyụọ, VLAN ON / Gbanyụọ, SFP ọdụ ụgbọ mmiri edozi ọsọ, NA dị ka 100M ọsọ
    Netwọk eji arụ ọrụ: STP/RSTP
    Nkwado Multicast: IGMP Snooping V1/V2/V3
    VLAN: IEEE 802.1Q 4K VLAN
    QOS: Port, 1Q, ACL, DSCP, CVLAN, SVLAN, DA, SA
    Ọrụ nchịkwa: WEB
    Nlekọta nyocha: enyo ọdụ ụgbọ mmiri, Ping

    8

    Dee ozi gị ebe a ziga anyị ya